<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Cooling Tunnels &#8211; Valiant Industries</title>
	<atom:link href="https://valiantindustriesllc.com/cooling-tunnels/feed/" rel="self" type="application/rss+xml" />
	<link>https://valiantindustriesllc.com</link>
	<description></description>
	<lastBuildDate>Fri, 27 Oct 2023 14:41:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://valiantindustriesllc.com/wp-content/uploads/cropped-favicon-150x150.jpg</url>
	<title>Cooling Tunnels &#8211; Valiant Industries</title>
	<link>https://valiantindustriesllc.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GC Evans Cooling Tunnels</title>
		<link>https://valiantindustriesllc.com/gc-evans-cooling-tunnels-2/</link>
		
		<dc:creator><![CDATA[Valiant]]></dc:creator>
		<pubDate>Thu, 26 Oct 2023 12:05:24 +0000</pubDate>
				<guid isPermaLink="false">http://158.106.129.7/~valianttes/gc-evans-cooling-tunnels-2/</guid>

					<description><![CDATA[GC Evans Cooling Tunnels are designed to require the minimum of mechanical maintenance. All key components are accessible and easily replaced. We engineer our Cooling Tunnels on the principle that the customer should pay it a minimum of attention – “Set It and Forget It”.
300 Series stainless construction throughout
Choice of cooling water delivery systems: Evaporative or Conductive
Removable panels along both sides for easy interior access
Internal belt return system to minimize external water
High strength, heavy duty modular plastic belt with infeed and discharge finger transfer plates
Zoned cooling for maximum process benefit without thermal shock damage to containers
Customized water usage systems with supplied heat exchanger for efficient utilization of the facility’s cooling tower, chilled water or fresh water
Pre-wired and pre-tested custom control package with digital display process controller to accurately maintain temperature setting by zones]]></description>
										<content:encoded><![CDATA[GC Evans Cooling Tunnels are designed to require the minimum of mechanical maintenance. All key components are accessible and easily replaced. We engineer our Cooling Tunnels on the principle that the customer should pay it a minimum of attention – “Set It and Forget It”.
300 Series stainless construction throughout
Choice of cooling water delivery systems: Evaporative or Conductive
Removable panels along both sides for easy interior access
Internal belt return system to minimize external water
High strength, heavy duty modular plastic belt with infeed and discharge finger transfer plates
Zoned cooling for maximum process benefit without thermal shock damage to containers
Customized water usage systems with supplied heat exchanger for efficient utilization of the facility’s cooling tower, chilled water or fresh water
Pre-wired and pre-tested custom control package with digital display process controller to accurately maintain temperature setting by zones]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Simplimatic Can Warmer</title>
		<link>https://valiantindustriesllc.com/simplimatic-can-warmer/</link>
		
		<dc:creator><![CDATA[Eli McGuire]]></dc:creator>
		<pubDate>Wed, 19 Jul 2023 16:32:23 +0000</pubDate>
				<guid isPermaLink="false">https://valiantindustriesllc.com/?post_type=product&#038;p=11472</guid>

					<description><![CDATA[Can and Bottle Cooler and Warmer
Tunnel Warmer or Cooler for Cans and Bottles
6’ wide x 18’ long, raised rib Intralox mattop chain
4 ½” wide tabletop chain infeed conveyor with pneumatic cross-push cylinder for bottle induction
Most recently running square jars of pasta sauce
Two pumps
A little dirty from outside storage, but still in good/serviceable condition
Simplimatic Engineering Company]]></description>
										<content:encoded><![CDATA[Can and Bottle Cooler and Warmer
Tunnel Warmer or Cooler for Cans and Bottles
6’ wide x 18’ long, raised rib Intralox mattop chain
4 ½” wide tabletop chain infeed conveyor with pneumatic cross-push cylinder for bottle induction
Most recently running square jars of pasta sauce
Two pumps
A little dirty from outside storage, but still in good/serviceable condition
Simplimatic Engineering Company]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GC Evans Cooling Tunnels</title>
		<link>https://valiantindustriesllc.com/gc-evans-cooling-tunnels/</link>
		
		<dc:creator><![CDATA[Valiant]]></dc:creator>
		<pubDate>Tue, 28 Jul 2020 18:04:37 +0000</pubDate>
				<guid isPermaLink="false">https://valiantindustriesllc.com/equipment/import-placeholder-for-3821/</guid>

					<description><![CDATA[GC Evans Cooling Tunnels are designed to require the minimum of mechanical maintenance. All key components are accessible and easily replaced. We engineer our Cooling Tunnels on the principle that the customer should pay it a minimum of attention – “Set It and Forget It”.

<ul>

 	<li>300 Series stainless construction throughout</li>

 	<li>Choice of cooling water delivery systems: Evaporative or Conductive</li>

 	<li>Removable panels along both sides for easy interior access</li>

 	<li>Internal belt return system to minimize external water</li>

 	<li>High strength, heavy duty modular plastic belt with infeed and discharge finger transfer plates</li>

 	<li>Zoned cooling for maximum process benefit without thermal shock damage to containers</li>

 	<li>Customized water usage systems with supplied heat exchanger for efficient utilization of the facility’s cooling tower, chilled water or fresh water</li>

 	<li>Pre-wired and pre-tested custom control package with digital display process controller to accurately maintain temperature setting by zones</li>

 	<li>Discharge blower system to remove excess water from the containers</li>

 	<li>Strainer Tanks with dual stainless steel filters prior to pump suction</li>

 	<li>“Scuff resistant” internal guard rails</li>

 	<li>Built in one piece or full width sections for ease of shipment and installation</li>

 	<li>Internal CIP system</li>

 	<li>Large cleanouts</li>

 	<li>Dynamic transfer conveyor</li>

 	<li>Fresh water rinsing</li>

 	<li>Stainless steel wet-end pumps</li>

 	<li>Container dry off</li>

</ul>]]></description>
										<content:encoded><![CDATA[GC Evans Cooling Tunnels are designed to require the minimum of mechanical maintenance. All key components are accessible and easily replaced. We engineer our Cooling Tunnels on the principle that the customer should pay it a minimum of attention – “Set It and Forget It”.

<ul>

 	<li>300 Series stainless construction throughout</li>

 	<li>Choice of cooling water delivery systems: Evaporative or Conductive</li>

 	<li>Removable panels along both sides for easy interior access</li>

 	<li>Internal belt return system to minimize external water</li>

 	<li>High strength, heavy duty modular plastic belt with infeed and discharge finger transfer plates</li>

 	<li>Zoned cooling for maximum process benefit without thermal shock damage to containers</li>

 	<li>Customized water usage systems with supplied heat exchanger for efficient utilization of the facility’s cooling tower, chilled water or fresh water</li>

 	<li>Pre-wired and pre-tested custom control package with digital display process controller to accurately maintain temperature setting by zones</li>

 	<li>Discharge blower system to remove excess water from the containers</li>

 	<li>Strainer Tanks with dual stainless steel filters prior to pump suction</li>

 	<li>“Scuff resistant” internal guard rails</li>

 	<li>Built in one piece or full width sections for ease of shipment and installation</li>

 	<li>Internal CIP system</li>

 	<li>Large cleanouts</li>

 	<li>Dynamic transfer conveyor</li>

 	<li>Fresh water rinsing</li>

 	<li>Stainless steel wet-end pumps</li>

 	<li>Container dry off</li>

</ul>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
